Current Sensors
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Show Filters
Reset Filters
Apply Filters
CategorySensors / Current Sensors / Current Sensors
Records 1,649
Page 4/55
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Polarization | Mounting Type | Package / Case | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LEM |
SENSOR CURRENT FLUX 25A AC/DC |
1,033 |
|
CKSR | AC/DC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±0.8% | 4.75V ~ 5.25V | 0.3µs | 20mA | -40°C ~ 105°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT FLUX 6A AC/DC |
4,089 |
|
CKSR | AC/DC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±0.8% | 4.75V ~ 5.25V | 0.3µs | 20mA | -40°C ~ 105°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT FLUX 15A AC/DC |
1,959 |
|
CKSR | AC/DC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±1% | ±0.8% | 4.75V ~ 5.25V | 0.3µs | 20mA | -40°C ~ 105°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT FLUX 6A AC/DC |
6,911 |
|
CASR | AC/DC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±0.8% | 4.75V ~ 5.25V | 0.3µs | 20mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 25A AC/DC |
617 |
|
LTS | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
LEM |
SENSOR CURRENT HALL 6A AC/DC |
9 |
|
LTS | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
LEM |
SENSOR CURRENT HALL 15A AC/DC |
9,492 |
|
LTS | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.6mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Tamura |
SENSOR CURRENT HALL 100A AC/DC |
3,180 |
|
- | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 25A AC/DC |
7,992 |
|
LTSR | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
LEM |
SENSOR CURRENT FLUX 50A AC/DC |
1,701 |
|
CASR | AC/DC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±0.8% | 4.75V ~ 5.25V | 0.3µs | 20mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL SELECTABLE |
6,540 |
|
LAX | AC/DC | Hall Effect, Closed Loop | 16.7A, 25A, 33.3A, 50A, 100A (Selectable) | 1 | Ratiometric, Current | 0.5mA/A | DC ~ 300kHz | ±0.1% | ±0.91% | ±11.4V ~ 15.75V | 0.2µs | 62mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 200A AC/DC |
15,840 |
|
HASS | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 100A AC/DC |
7,140 |
|
HASS | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 50A AC/DC |
9,384 |
|
HASS | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 8A, 12A, 25A |
12,758 |
|
LAH | AC/DC | Hall Effect, Closed Loop | 8A, 12A, 25A (Selectable) | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.2% | ±0.3% | ±12V ~ 15V | 0.5µs | 35mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 100A AC/DC |
47 |
|
LAH | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.25% | ±12V ~ 15V | 0.5µs | 60mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 50A AC/DC |
488 |
|
LAH | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.25% | ±12V ~ 15V | 0.5µs | 35mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
CR Magnetics Inc. |
SENSOR CURRENT SWITCH 100A NPN |
6,708 |
|
CR9300 | AC | Current Switch | 100A | 1 | NPN | - | 50Hz ~ 400kHz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | Bidirectional | - | Module, Single Pass Through | - |
|
|
LEM |
SENSOR CURRENT HALL 300A AC/DC |
7,788 |
|
HASS | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 400A AC/DC |
8,136 |
|
HASS | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
Tamura |
SENSOR CURRENT HALL 100A AC/DC |
14,700 |
|
- | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | Bidirectional | Through Hole | Module | - |
|
|
Tamura |
SENSOR CURRENT HALL 50A AC/DC |
20,448 |
|
- | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 500A AC/DC |
8,154 |
|
HASS | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 10A AC/DC |
8,388 |
|
HY | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 10mA | -10°C ~ 80°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL SELECTABLE |
7,896 |
|
LA | AC/DC | Hall Effect, Closed Loop | 5A, 6A, 8A, 12A, 25A (Selectable) | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 50A AC/DC |
15,648 |
|
LA | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.65% | ±12V ~ 15V | 1µs | 60mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
LEM |
SENSOR CURRENT HALL 200A AC/DC |
178 |
|
HAS | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 100A AC/DC |
13 |
|
HAS | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | Bidirectional | Through Hole | Module | - |
|
|
LEM |
SENSOR CURRENT HALL 100A AC/DC |
32,766 |
|
LA | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.45% | ±12V ~ 15V | 1µs | 10mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
LEM |
SENSOR CURRENT HALL 150A AC/DC |
3,100 |
|
LA | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±1% | ±0.5% | ±12V ~ 15V | 0.5µs | 10mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |