CKSR 15-NP

For Reference Only
Part Number | CKSR 15-NP | ||||||||||||||||||
PNEDA Part # | CKSR-15-NP | ||||||||||||||||||
Description | SENSOR CURRENT FLUX 15A AC/DC | ||||||||||||||||||
Manufacturer | LEM | ||||||||||||||||||
Unit Price |
|
||||||||||||||||||
In Stock | 1,959 | ||||||||||||||||||
Warehouses | Shipped from Hong Kong SAR | ||||||||||||||||||
Estimated Delivery | Mar 16 - Mar 21 (Choose Expedited Shipping) | ||||||||||||||||||
Guarantee | Up to 1 year [PNEDA-Warranty]* | ||||||||||||||||||
Free shipping on orders over $100. PNEDA is willing to provide you with better services.
|
|||||||||||||||||||
|
CKSR 15-NP Resources
Brand | LEM |
ECAD Module |
![]() |
Mfr. Part Number | CKSR 15-NP |
Category | Sensors › Current Sensors › Current Sensors |
Datasheet |
Payment Method






- Penda is not limited to cash transfers. Checks and bill transfers are also accepted.
- If you need the detailed invoice or tax ID,please email us.
- Some orders may require a minimum amount of $100.00.
- Cheque or cash on delivery, processing may take an additional 3-5 days.
Logistics Mode





- Delivery time: At the same day (Order deadline is 2pm, HK Time).
- Delivery date: usually 2 to 7 working days.
- It is unable to appoint a date of delivery.
- Tracking number will be sent once your order has been shipped.
- It may take up to 24 hours before carriers display the info.
Notes
- Please confirm the specifications of the products when ordering.
- If you have special order instructions,please note it on the ordering pages.
- Registered users can log in to the account to view the order status.
- You can email us to change the order details before shipment.
- Orders cannot be canceled after shipping the packages.
At PNEDA, we strive to be the industry leader by quickly and reliably supplying high-quality electronic components to our clients.
Our approach is built around proving our clients with three key advantages:
Prompt Responsiveness
Our team responds quickly to your requests, and gets to work immediately to find your parts.
Guaranteed Quality
Our quality-control processes guard against counterfeits while ensuring reliability and performance.
Global Access
Our worldwide network of trusted resources allows us to find and deliver the specific parts you need.
Hot search vocabulary
- CKSR 15-NP Datasheet
- where to find CKSR 15-NP
- LEM
- LEM CKSR 15-NP
- CKSR 15-NP PDF Datasheet
- CKSR 15-NP Stock
- CKSR 15-NP Pinout
- Datasheet CKSR 15-NP
- CKSR 15-NP Supplier
- LEM Distributor
- CKSR 15-NP Price
- CKSR 15-NP Distributor
CKSR 15-NP Specifications
Manufacturer | LEM USA Inc. |
Series | CKSR |
For Measuring | AC/DC |
Sensor Type | Flux Gate, Closed Loop |
Current - Sensing | 15A |
Number of Channels | 1 |
Output | Ratiometric, Voltage |
Sensitivity | 41.67mV/A |
Frequency | 300kHz |
Linearity | ±1% |
Accuracy | ±0.8% |
Voltage - Supply | 4.75V ~ 5.25V |
Response Time | 0.3µs |
Current - Supply (Max) | 20mA |
Operating Temperature | -40°C ~ 105°C |
Polarization | Bidirectional |
Mounting Type | Through Hole |
Package / Case | Module |
Supplier Device Package | - |
The Products You May Be Interested In
Manufacturer Silicon Labs Series - For Measuring AC Sensor Type Transformer w/Conditioning Current - Sensing 20A Number of Channels 1 Output Configurable (3-Modes) Sensitivity 98mV/A Frequency 50kHz ~ 1MHz Linearity - Accuracy ±5% Voltage - Supply 2.7V ~ 5.5V Response Time - Current - Supply (Max) 7mA Operating Temperature -40°C ~ 125°C Polarization Unidirectional Mounting Type Surface Mount Package / Case 20-SOIC (0.295", 7.50mm Width) Supplier Device Package 20-SOIC |
Manufacturer Tamura Series L31SXXXS05S For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 50A Number of Channels 1 Output Ratiometric, Voltage Sensitivity - Frequency DC ~ 100kHz Linearity ±0.5% Accuracy - Voltage - Supply 5V Response Time 5µs Current - Supply (Max) 15mA Operating Temperature -40°C ~ 85°C Polarization Bidirectional Mounting Type Chassis Mount Package / Case Module, Single Pass Through Supplier Device Package - |
Manufacturer AKM Semiconductor Inc. Series - For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 35.7A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 37mV/A Frequency - Linearity - Accuracy ±1.3% Voltage - Supply 3.3V Response Time 0.5µs Current - Supply (Max) 6.2mA Operating Temperature -40°C ~ 90°C Polarization Bidirectional Mounting Type Surface Mount Package / Case 24-LSSOP (0.220", 5.60mm Width), 10 Leads Supplier Device Package 24-VSOP |
Manufacturer LEM USA Inc. Series DHR For Measuring AC/DC Sensor Type Hall Effect, Open Loop Current - Sensing 500A Number of Channels 1 Output Ratiometric, 4mA ~ 20mA Sensitivity - Frequency DC ~ 6kHz Linearity ±1% Accuracy ±1% Voltage - Supply 20V ~ 50V Response Time 150ms Current - Supply (Max) 30mA Operating Temperature -40°C ~ 70°C Polarization Bidirectional Mounting Type Panel Mount Package / Case Module Supplier Device Package - |
Manufacturer CR Magnetics Inc. Series CR5200 For Measuring DC Sensor Type Magnetic Modulator, Closed Loop Current - Sensing 2A Number of Channels 1 Output Ratiometric, 4mA ~ 20mA Sensitivity - Frequency DC Linearity - Accuracy ±1% Voltage - Supply 24V Response Time 250ms Current - Supply (Max) 100mA Operating Temperature 0°C ~ 50°C Polarization Unidirectional Mounting Type DIN Rail, Panel Package / Case Module Supplier Device Package - |