Series | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Number of Poles | Actuator Type | Illumination | Illumination Voltage (Nominal) | Mounting Type | Approvals |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Weidmuller |
CB PROTECTOR 1077 2P C 3A ACDC |
6,516 |
|
SUxxxUC | Thermal Magnetic | 3A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
|
Weidmuller |
CIR BRKR MAG-HYDR 10A 120VAC |
5,814 |
|
9926 | Magnetic (Hydraulic Delay) | 10A | 120V | - | 1 | Lever | - | - | DIN Rail | CE, CSA C22.2 No 235, UL1077, VDE |
|
|
Weidmuller |
CB PROTECTOR 1077 3P C 10A ACDC |
6,024 |
|
SUxxxUC | Thermal Magnetic | 10A | 277V | - | 3 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
|
Weidmuller |
CB PROTECTOR 1077 3P C 20A ACDC |
8,226 |
|
SUxxxUC | Thermal Magnetic | 20A | 277V | - | 3 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
|
Weidmuller |
CB PROTECTOR 1077 3P C 30A ACDC |
6,624 |
|
SUxxxUC | Thermal Magnetic | 30A | 277V | - | 3 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 40A ACDC |
7,200 |
|
BRxxxUC | Thermal Magnetic | 40A | 240V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 15A ACDC |
7,650 |
|
BRxxxUC | Thermal Magnetic | 15A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 4A ACDC |
6,300 |
|
BRxxxUC | Thermal Magnetic | 4A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 5A ACDC |
4,932 |
|
BRxxxUC | Thermal Magnetic | 5A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 6A ACDC |
7,722 |
|
BRxxxUC | Thermal Magnetic | 6A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 15A ACDC |
4,626 |
|
BRxxxUC | Thermal Magnetic | 15A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 1A ACDC |
8,100 |
|
BRxxxUC | Thermal Magnetic | 1A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 40A ACDC |
7,146 |
|
BRxxxUC | Thermal Magnetic | 40A | 240V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 5A ACDC |
6,660 |
|
BRxxxUC | Thermal Magnetic | 5A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 20A ACDC |
6,480 |
|
BRxxxUC | Thermal Magnetic | 20A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 3A ACDC |
6,120 |
|
BRxxxUC | Thermal Magnetic | 3A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 30A ACDC |
4,986 |
|
BRxxxUC | Thermal Magnetic | 30A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 25A ACDC |
8,154 |
|
BRxxxUC | Thermal Magnetic | 25A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 30A ACDC |
8,712 |
|
BRxxxUC | Thermal Magnetic | 30A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 8A ACDC |
4,392 |
|
BRxxxUC | Thermal Magnetic | 8A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 16A ACDC |
5,328 |
|
BRxxxUC | Thermal Magnetic | 16A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 20A ACDC |
5,742 |
|
BRxxxUC | Thermal Magnetic | 20A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 2A ACDC |
4,914 |
|
BRxxxUC | Thermal Magnetic | 2A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 10A ACDC |
5,904 |
|
BRxxxUC | Thermal Magnetic | 10A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 1A ACDC |
5,148 |
|
BRxxxUC | Thermal Magnetic | 1A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P C 3A ACDC |
8,658 |
|
BRxxxUC | Thermal Magnetic | 3A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 10A ACDC |
5,058 |
|
BRxxxUC | Thermal Magnetic | 10A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
CB MCB 489 2P D 2A ACDC |
8,640 |
|
BRxxxUC | Thermal Magnetic | 2A | 480V | 125V | 2 | Lever | None | - | DIN Rail | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
|
Weidmuller |
QZ-2-13-D-2-03 |
5,958 |
|
9926 | Magnetic (Hydraulic Delay) | 3A | - | - | - | Lever | - | - | DIN Rail | CE, CSA, UL, VDE |
|
|
Weidmuller |
CIR BRKR MAG-HYDR 6A 240VAC |
7,434 |
|
9926 | Magnetic (Hydraulic Delay) | 6A | 240V | - | 2 | Lever | - | - | DIN Rail | CE, CSA C22.2 No 235, UL1077, VDE |