Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
6,024 |
|
HQ | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 48.8mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 30A CHASS MNT |
5,724 |
|
HZ | Single Phase | Single Stage | - | 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 900µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 15A CHASS MNT |
4,356 |
|
T | Single Phase | Two Stage | - | 250V | - | - | 15A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 5.07mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 7A CHASSIS MOUNT |
7,146 |
|
BCF | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 7A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 7A CHASSIS MOUNT |
5,220 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 7A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 2.43mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 7A CHASSIS MOUNT |
7,992 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 7A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 2.43mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 16A CHASSIS MOUNT |
8,766 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 16A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 2.01mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 16A CHASSIS MOUNT |
7,038 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 16A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 2.01mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 30A CHASSIS MOUNT |
7,848 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 1.6mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 42A CHASSIS MOUNT |
7,128 |
|
BCF | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 42A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 42A CHASSIS MOUNT |
8,496 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 42A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 1.6mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 55A CHASSIS MOUNT |
6,660 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 55A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 1.8mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 75A CHASSIS MOUNT |
8,694 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 75A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 1.06mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 55A CHASSIS MOUNT |
7,704 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 55A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 1.8mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 130A CHASSIS MOUNT |
6,624 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 130A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 550µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 100A CHASSIS MOUNT |
4,986 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 100A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 800µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 130A CHASSIS MOUNT |
5,238 |
|
BCF | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 130A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M10) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 130A CHASSIS MOUNT |
6,498 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 130A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 550µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 150A CHASSIS MOUNT |
8,730 |
|
AYC | Three Phase (Wye) | Single Stage | - | - | 277V | 480V | 150A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 180A CHASSIS MOUNT |
6,030 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 180A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 340µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 520VAC 250A CHASS |
6,516 |
|
APS | Three Phase (Delta) | Three Stage | - | 520V | - | - | 250A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 520VAC 400A CHASS |
5,382 |
|
APS | Three Phase (Delta) | Three Stage | - | 520V | - | - | 400A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 520VAC 250A CHASS |
4,950 |
|
APH | Three Phase (Delta) | Three Stage | - | 520V | - | - | 250A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 520VAC 600A CHASS |
7,596 |
|
APS | Three Phase (Delta) | Three Stage | - | 520V | - | - | 600A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 690VAC 250A CHASS |
5,832 |
|
APH | Three Phase (Delta) | Three Stage | - | 690V | - | - | 250A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
8,892 |
|
B | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.76mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A CHASS MNT |
7,884 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 5A CHASS MNT |
8,244 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 5A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 516µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A CHASS MNT |
8,460 |
|
B | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.86mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
7,740 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.76mH |