Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
269 |
|
R | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 3.52mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
2,664 |
|
Z | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 13.77mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
4,608 |
|
HQ | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 32.18mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
3,330 |
|
T | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 18.5mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 30A CHASS MNT |
7,488 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (10-32) | 1.73mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
3,942 |
|
Q | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 48.8mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 75A CHASSIS MOUNT |
8,622 |
|
BCF | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 75A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 36A CHASSIS MOUNT |
8,424 |
|
FCD | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 36A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 100A CHASSIS MOUNT |
7,884 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 100A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 800µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 180A CHASSIS MOUNT |
3,726 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 180A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 340µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
8,424 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 495µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A CHASS MNT |
5,058 |
|
B | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 1.86mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A CHASS MNT |
4,878 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.86mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
4,374 |
|
R | Single Phase | Two Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 990µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
6,228 |
|
EP | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
7,470 |
|
RK | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
3,114 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7.06mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 15A CHASS MNT |
5,508 |
|
EMC | Single Phase | Two Stage | - | 250V | - | - | 15A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
6,750 |
|
EP | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
5,904 |
|
T | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 16A CHASSIS MOUNT |
8,226 |
|
BCF | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 16A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 36A CHASSIS MOUNT |
8,388 |
|
FCD | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 36A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 45A CHASSIS MOUNT |
5,364 |
|
A | Three Phase (Wye) | Two Stage | - | - | 250V | 440V | 45A | 50/60Hz | General Purpose | CSA, UL | -10°C ~ 40°C | Chassis Mount | Threaded Post (1/4-20) | 2.22mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 80A CHASSIS MOUNT |
3,978 |
|
FCD | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 80A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 110A CHASSIS MOUNT |
8,910 |
|
FCD | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 110A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 180A CHASSIS MOUNT |
5,490 |
|
FCD | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 180A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 150A CHASSIS MOUNT |
3,744 |
|
FCD | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 150A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 150A CHASSIS MOUNT |
8,316 |
|
AYC | Three Phase (Wye) | Single Stage | - | - | 277V | 480V | 150A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 690VAC 250A CHASS |
4,608 |
|
APS | Three Phase (Delta) | Three Stage | - | 690V | - | - | 250A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 690VAC 400A CHASS |
5,310 |
|
APS | Three Phase (Delta) | Three Stage | - | 690V | - | - | 400A | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |