CategoryPower / Power Supplies - Off-Board / Off-Board - AC DC Converters
ManufacturerTDK-Lambda Americas Inc.
Records 2,741
Page 16/92
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TDK-Lambda |
AC/DC CONVERTER 15V 1500W |
8,586 |
|
RWS1500B (1500W) | Enclosed | 1 | 85 ~ 265 VAC, 120 ~ 340 VDC | 15V | - | - | - | 100A | 1500W | ITE (Commercial) | 4kV | 85% | -20°C ~ 60°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 10.28" L x 5.00" W x 2.48" H (261.0mm x 127.0mm x 63.0mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 48V 2500W |
5,814 |
|
TH (2500W) | Front End | 1 | 90 ~ 264 VAC | 48V | - | - | - | 50A | 2500W | ITE (Commercial) | - | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, I²C™ Interface, Load Sharing, PFC, Remote Sense, Standby Output | Rack Mount | 14.25" L x 4.00" W x 1.69" H (362.0mm x 101.6mm x 42.9mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 24V 30W |
6,300 |
|
CUS30M (30W) | Open Frame | 1 | 85 ~ 265 VAC | 24V | - | - | - | 1.25A | 30W | ITE (Commercial), Medical | 4kV | 90% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.1mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 12V 30W |
8,172 |
|
CUS30M (30W) | Open Frame | 1 | 85 ~ 265 VAC | 12V | - | - | - | 2.5A | 30W | ITE (Commercial), Medical | 4kV | 88% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.1mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 48V 30W |
6,324 |
|
CUS30M (30W) | Open Frame | 1 | 85 ~ 265 VAC | 48V | - | - | - | 630mA | 30W | ITE (Commercial), Medical | 4kV | 90% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.1mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 3.3V 10W |
4,734 |
|
ZWS10B (10W) | Open Frame | 1 | 85 ~ 265 VAC | 3.3V | - | - | - | 2A | 10W | ITE (Commercial) | 3kV | 70% | -10°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Load Sharing, PFC, Universal Input | Chassis Mount | 4.14" L x 1.97" W x 0.83" H (105.1mm x 50.0mm x 21.0mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 30W |
6,300 |
|
CUS30M (30W) | Open Frame | 1 | 85 ~ 265 VAC | 15V | - | - | - | 2A | 30W | ITE (Commercial), Medical | 4kV | 88% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.1mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 36V 30W |
5,904 |
|
CUS30M (30W) | Open Frame | 1 | 85 ~ 265 VAC | 36V | - | - | - | 840mA | 30W | ITE (Commercial), Medical | 4kV | 90% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.1mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 18V 31W |
6,072 |
|
CUS30M (30W) | Open Frame | 1 | 85 ~ 265 VAC | 18V | - | - | - | 1.7A | 31W | ITE (Commercial), Medical | 4kV | 88% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.1mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 25W |
6,180 |
|
DRL (10-100W) | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 373 VDC | 15V | - | - | - | 1.68A | 25W | Hazardous Locations, ITE (Commercial) | 3kV | 88% | -20°C ~ 71°C (With Derating) | Adjustable Output, Universal Input | DIN Rail | 2.19" L x 1.42" W x 3.58" H (55.6mm x 36.1mm x 90.9mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 24V 60W |
6,504 |
|
CUS60M (60W) | Open Frame | 1 | 85 ~ 265 VAC | 24V | - | - | - | 2.5A | 60W | ITE (Commercial), Medical | 4kV | 90% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 1.05" H (76.2mm x 50.8mm x 26.7mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 5V 30W |
5,958 |
|
CUS60M (60W) | Open Frame | 1 | 85 ~ 265 VAC | 5V | - | - | - | 6A | 30W | ITE (Commercial), Medical | 4kV | 81% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 1.05" H (76.2mm x 50.8mm x 26.7mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 48V 60W |
7,290 |
|
CUS60M (60W) | Open Frame | 1 | 85 ~ 265 VAC | 48V | - | - | - | 1.25A | 60W | ITE (Commercial), Medical | 4kV | 90% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 1.05" H (76.2mm x 50.8mm x 26.7mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 60W |
6,240 |
|
CUS60M (60W) | Open Frame | 1 | 85 ~ 265 VAC | 15V | - | - | - | 4A | 60W | ITE (Commercial), Medical | 4kV | 89% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 1.05" H (76.2mm x 50.8mm x 26.7mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 18V 59W |
8,478 |
|
CUS60M (60W) | Open Frame | 1 | 85 ~ 265 VAC | 18V | - | - | - | 3.25A | 59W | ITE (Commercial), Medical | 4kV | 89% | -20°C ~ 70°C (With Derating) | PFC, Remote Sense | Chassis Mount | 3.00" L x 2.00" W x 1.05" H (76.2mm x 50.8mm x 26.7mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 54W |
6,084 |
|
DRL (10-100W) | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 373 VDC | 15V | - | - | - | 3.6A | 54W | Hazardous Locations, ITE (Commercial) | 3kV | 87% | -20°C ~ 71°C (With Derating) | Adjustable Output, Universal Input | DIN Rail | 2.19" L x 2.13" W x 3.58" H (55.6mm x 54.0mm x 90.9mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 51W |
8,964 |
|
DRB (15-100W) | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 373 VDC | 15V | - | - | - | 3.4A | 51W | Hazardous Locations, Industrial, ITE (Commercial) | 3kV | 90% | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | DIN Rail | 3.54" L x 1.18" W x 2.95" H (89.9mm x 30.0mm x 74.9mm) |
|
|
TDK-Lambda |
AC-DC MEDICAL 115-230VAC OUTPUT |
4,950 |
|
CSS65A (65W) | Open Frame | 1 | 90 ~ 264 VAC | 28V | - | - | - | 2.33A | 65W | ITE (Commercial), Medical | 4kV | 89% | 0°C ~ 70°C (With Derating) | Remote Sense, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 24V 88W |
8,622 |
|
DRL (10-100W) | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 373 VDC | 24V | - | - | - | 4.2A | 101W | Hazardous Locations, ITE (Commercial) | 3kV | 90% | -20°C ~ 71°C (With Derating) | Adjustable Output, Universal Input | DIN Rail | 2.19" L x 2.83" W x 3.58" H (55.6mm x 72.0mm x 90.9mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 12V 100W |
6,228 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | 8.33A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 24V 100W |
6,642 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 24V | - | - | - | 4.16A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 36V 100W |
5,310 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 36V | - | - | - | 2.77A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 28V 100W |
6,768 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 28V | - | - | - | 3.57A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 100W |
5,094 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | 6.66A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 18V 100W |
6,012 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 18V | - | - | - | 5.55A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 12V 100W |
8,352 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | 8.33A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Baseplate, Universal Input | Chassis Mount | 4.57" L x 2.34" W x 1.35" H (116.0mm x 59.4mm x 34.2mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 24V 100W |
5,382 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 24V | - | - | - | 4.16A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Baseplate, Universal Input | Chassis Mount | 4.57" L x 2.34" W x 1.35" H (116.0mm x 59.4mm x 34.2mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 15V 100W |
4,392 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | 6.66A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Baseplate, Universal Input | Chassis Mount | 4.57" L x 2.34" W x 1.35" H (116.0mm x 59.4mm x 34.2mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 28V 100W |
8,478 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 28V | - | - | - | 3.57A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Baseplate, Universal Input | Chassis Mount | 4.57" L x 2.34" W x 1.35" H (116.0mm x 59.4mm x 34.2mm) |
|
|
TDK-Lambda |
AC/DC CONVERTER 36V 100W |
7,686 |
|
CUS100ME (100W) | Open Frame | 1 | 85 ~ 264 VAC | 36V | - | - | - | 2.77A | 100W | Household Appliances, ITE (Commercial), Medical | 4kV | 94% | -20°C ~ 85°C (With Derating) | Baseplate, Universal Input | Chassis Mount | 4.57" L x 2.34" W x 1.35" H (116.0mm x 59.4mm x 34.2mm) |