Schurter Power Line Filter Modules
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Show Filters
Reset Filters
Apply Filters
CategoryPassive Components / Filters / Power Line Filter Modules
ManufacturerSchurter
Records 461
Page 9/16
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schurter |
LINE FILTER 125/250VAC 20A CHASS |
7,308 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 20A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 30A CHASS |
2,466 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 30A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Threaded Post (M4) | - |
|
|
Schurter |
LINE FILTER 125/250VAC 60A CHASS |
5,040 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 60A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Threaded Post (M6) | - |
|
|
Schurter |
LINE FILTER 480VAC 36A CHASS MNT |
5,454 |
|
FMAC ECO | Three Phase (Delta) | Single Stage | - | 480V | - | - | 36A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 570µH |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
7,236 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
5,184 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 3A CHAS |
6,120 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
8,334 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 12A CHASS |
6,084 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 12A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 16A CHASS |
7,938 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 16A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 4A CHAS |
8,892 |
|
FMLB-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 4A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.5mH |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
8,532 |
|
FMLB-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
8,586 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
8,406 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
5,328 |
|
FMW-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
7,848 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 3A CHAS |
4,140 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 3A CHAS |
8,442 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
5,364 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 4A CHAS |
6,048 |
|
FMLB-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 4A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.5mH |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
6,894 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
7,128 |
|
FMLB-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
|
Schurter |
LINE FILTER 125/250VAC 3A CHAS |
3,978 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
7,614 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
6,156 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 3A CHAS |
6,876 |
|
FMAB NEO | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
Schurter |
LINE FILTER 125/250VAC 3A CHAS |
7,218 |
|
FMW-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2mH |
|
|
Schurter |
LINE FILTER 125/250VAC 6A CHAS |
4,554 |
|
FMW-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
|
Schurter |
LINE FILTER 125/250VAC 1A CHAS |
5,472 |
|
FMW-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 1A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 10mH |
|
|
Schurter |
LINE FILTER 125/250VAC 2A CHAS |
7,038 |
|
FMLB-41 | Single Phase | Single Stage | - | 125V, 250V | - | - | 2A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 4mH |