Schaffner EMC Power Line Filter Modules
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Show Filters
Reset Filters
Apply Filters
CategoryPassive Components / Filters / Power Line Filter Modules
ManufacturerSchaffner EMC
Records 825
Page 26/28
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 20A CHASS MNT |
3,546 |
|
FN 660 | Single Phase | Two Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 480µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 1.8A CHASS |
2,934 |
|
FN 670 | Single Phase | Two Stage | - | 250V | - | - | 1.8A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 7.2mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
2,124 |
|
FN 670 | Single Phase | Two Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 12.2mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
7,218 |
|
FN 670 | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 7mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
8,334 |
|
FN 670 | Single Phase | Two Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 10.4mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 1A CHASS MNT |
2,034 |
|
FN 680 | Single Phase | Two Stage | - | 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | 22.5mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 4A CHASS MNT |
8,316 |
|
FN 680 | Single Phase | Two Stage | - | 250V | - | - | 4A | DC ~ 400Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | 8mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6.5A CHASS |
4,248 |
|
FN 680 | Single Phase | Two Stage | - | 250V | - | - | 6.5A | DC ~ 400Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | 4.1mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6.5A CHASS |
4,284 |
|
FN 680 | Single Phase | Two Stage | - | 250V | - | - | 6.5A | DC ~ 400Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Wire Leads | 4.1mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
3,492 |
|
FN 680 | Single Phase | Two Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | 4mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 30A CHASS MNT |
4,734 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 30A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
8,244 |
|
FN 2310 | Single Phase | Single Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 9.6mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
5,040 |
|
FN 2310 | Single Phase | Single Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 36.9mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
3,096 |
|
FN 2310 | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 19.3mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
8,838 |
|
FN 2310 | Single Phase | Single Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 9.6mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
6,264 |
|
FN 2320 | Single Phase | Two Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.1mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
8,640 |
|
FN 2320 | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.9mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
5,346 |
|
FN 2320 | Single Phase | Two Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.3mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 20A CHASS MNT |
7,416 |
|
FN 2320 | Single Phase | Two Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
7,344 |
|
FN 610 | Single Phase | Single Stage | - | 250V | - | - | 10A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 450µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 1A CHASS MNT |
4,536 |
|
FN 610 | Single Phase | Single Stage | - | 250V | - | - | 1A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 3mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
8,064 |
|
FN 610 | Single Phase | Single Stage | - | 250V | - | - | 3A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
4,644 |
|
FN 610 | Single Phase | Single Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 100A CHASS |
3,636 |
|
FN 612 | Single Phase | Single Stage | - | 250V | - | - | 100A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M6) | 200µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 10A CHASS MNT |
3,312 |
|
FN 612 | Single Phase | Single Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 450µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 16A CHASS MNT |
7,362 |
|
FN 2060 | Single Phase | Two Stage | - | 250V | - | - | 16A | DC ~ 400Hz | Safety | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 650µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
6,768 |
|
FN 2360 | Single Phase | Two Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 400µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
6,012 |
|
FN 2360 | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.7mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
6,912 |
|
FN 2360 | Single Phase | Two Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 400µH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
2,430 |
|
FN 2360 | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.7mH |