CategoryPassive Components / Filters / Power Line Filter Modules
ManufacturerSchaffner EMC
Records 825
Page 20/28
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schaffner EMC |
LINE FILTER 200A CHASSIS MOUNT |
7,920 |
|
FN 3270 | Three Phase (Delta) | Three Stage | - | - | 300V | 520V | 200A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
Schaffner EMC |
LINE FILTER 520/300VAC 600A CHAS |
7,704 |
|
FN 3311 | Three Phase (Delta) | Single Stage | - | 520V, 300V | 300V | 520V | 600A | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
Schaffner EMC |
LINE FILTER 250VAC 1A CHASS MNT |
6,462 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 12mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
2,556 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 3A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.5mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
7,272 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 2.5mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 12A CHASS MNT |
6,642 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 12A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 700µH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
6,264 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 1mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 1A CHASS MNT |
7,866 |
|
FN 2020 | Single Phase | Single Stage | - | 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 12mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 16A CHASS MNT |
8,532 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 16A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
5,850 |
|
FN 2060 | Single Phase | Two Stage | - | 250V | - | - | 3A | DC ~ 400Hz | Safety | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.5mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 1A CHASS MNT |
7,506 |
|
FN 2030 | Single Phase | Single Stage | - | 250V | - | - | 1A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 20mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 3A CHAS |
5,058 |
|
FN 2070 | Single Phase | Two Stage | - | 110V, 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 9.8mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
5,652 |
|
FN 2450 | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 10.5mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 16A CHASS MNT |
8,280 |
|
FN 2450 | Single Phase | Single Stage | - | 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1.84mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 12A CHASS |
3,726 |
|
FN 2090 | Single Phase | Two Stage | - | 110V, 250V | - | - | 12A | DC ~ 400Hz | Safety | CE, CSA, ENEC, UR | -20°C ~ 100°C | Chassis Mount | Quick Connect | 4mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 12A CHASS |
7,182 |
|
FN 2080 | Single Phase | Two Stage | - | 110V, 250V | - | - | 12A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 3.25mH |
|
|
Schaffner EMC |
LINE FILTER 16A CHASSIS MOUNT |
4,626 |
|
FN 258 | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 16A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 250VAC 500MA TH |
5,202 |
|
FN 402 | Single Phase | Single Stage | - | 250V | - | - | 500mA | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 40mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 2.5A TH |
6,192 |
|
FN 402 | Single Phase | Single Stage | - | 250V | - | - | 2.5A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 2mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 4A TH |
7,164 |
|
FN 402 | Single Phase | Single Stage | - | 250V | - | - | 4A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 1mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 10A CHASSIS |
6,480 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 10A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
7,542 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 1mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 16A CHASS MNT |
6,930 |
|
FN 2010 | Single Phase | Single Stage | - | 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 700µH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 1A CHASS MNT |
3,780 |
|
FN 2020 | Single Phase | Single Stage | - | 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 12mH |
|
|
Schaffner EMC |
LINE FILTER 250VDC/VAC 20A CHAS |
4,122 |
|
FN 2010 | Single Phase | Single Stage | 250V | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 500MA TH |
2,250 |
|
FN 410 | Single Phase | Two Stage | - | 250V | - | - | 500mA | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 24mH |
|
|
Schaffner EMC |
LINE FILTER 250VDC/VAC 10A CHAS |
6,714 |
|
FN 2090 | Single Phase | Two Stage | 250V | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 8mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 8A CHASS MNT |
6,300 |
|
FN 2410 | Single Phase | Single Stage | - | 250V | - | - | 8A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 250VAC 30A CHASS MNT |
6,624 |
|
FN 2060 | Single Phase | Two Stage | - | 250V | - | - | 30A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 600µH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 16A CHASS |
7,848 |
|
FN 2080 | Single Phase | Two Stage | - | 110V, 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2.8mH |