Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Curtis Industries |
LINE FILTER 250VAC 10A CHASS MNT |
2,916 |
|
F1199 | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
|
|
Schaffner EMC |
LINE FILTER 250VAC 6A CHASS MNT |
7,722 |
|
FN 332 | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
|
Delta Electronics |
LINE FILTER 115/250VAC 6A CHAS |
6,264 |
|
DP | Single Phase | Two Stage | - | 115V, 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | - |
|
|
TDK-EPCOS |
LINE FILTER 250VDC/VAC 3A CHASS |
5,940 |
|
B84111F | Single Phase | Single Stage | 250V | 250V | - | - | 3A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.5mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A CHASS MNT |
7,038 |
|
B | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.86mH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 4A CHASS MNT |
7,128 |
|
FN 2030 | Single Phase | Single Stage | - | 250V | - | - | 4A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 14mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
5,832 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 495µH |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 3A CHASS |
3,526 |
|
RSEN | Single Phase | Single Stage | 250V | 250V | - | - | 3A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Qualtek |
LINE FILTER 115/250VAC 10A CHASS |
7,794 |
|
850 | Single Phase | Two Stage | - | 115V, 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | L1 - 1.2mH, L2 - 40µH |
|
|
Schaffner EMC |
LINE FILTER 250VAC 3A CHASS MNT |
6,048 |
|
FN 2030 | Single Phase | Single Stage | - | 250V | - | - | 3A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 14mH |
|
|
Qualtek |
LINE FILTER 115/250VAC 10A CHASS |
4,572 |
|
849 | Single Phase | Two Stage | - | 115V, 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | L1 - 1.2mH, L2 - 40µH |
|
|
Qualtek |
LINE FILTER 115/250VAC 20A CHASS |
8,982 |
|
851 | Single Phase | Single Stage | - | 115V, 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 85°C | Chassis Mount | Threaded Post (8-32) | 700µH |
|
|
Curtis Industries |
LINE FILTER 250VAC 10A CHASS MNT |
5,616 |
|
F1199 | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Threaded Post (8-32) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 5A CHASS MNT |
7,794 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 5A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 516µH |
|
|
Schurter |
LINE FILTER 250VDC/VAC 16A DIN |
6,642 |
|
FPBB RAIL | Single Phase | Two Stage | 250V | 250V | - | - | 16A | 50/60Hz | General Purpose | - | -40°C ~ 100°C | DIN Rail | Spring Cage | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
6,570 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 495µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
269 |
|
R | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 3.52mH |
|
|
Schurter |
LINE FILTER 43/80VDC 10A CHAS |
3,526 |
|
FMEB | DC | Single Stage | 43V, 80V | - | - | - | 10A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 200µH |
|
|
Curtis Industries |
LINE FILTER 250VAC 20A CHASS MNT |
4,140 |
|
F1700 | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - |
|
|
Delta Electronics |
LINE FILTER 115/250VAC 30A CHASS |
6,840 |
|
DP | Single Phase | Two Stage | - | 115V, 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Threaded Post (8-32) | 600µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
2,664 |
|
Z | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 13.77mH |
|
|
TDK-EPCOS |
LINE FILTER 250VDC/VAC 6A CHASS |
7,506 |
|
B84115E | Single Phase | Two Stage | 250V | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | L1 - 100µH, L2 - 4.7mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
4,608 |
|
HQ | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 32.18mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
3,330 |
|
T | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 18.5mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 30A CHASS MNT |
7,488 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (10-32) | 1.73mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
3,942 |
|
Q | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 48.8mH |
|
|
TDK-EPCOS |
LINE FILTER 520/300VAC 20A CHASS |
4,266 |
|
B84143A | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 20A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Delta Electronics |
LINE FILTER 480VAC 30A CHASS MNT |
5,526 |
|
TDV | Three Phase (Delta) | Single Stage | - | 480V | - | - | 30A | 50/60Hz | General Purpose | cURus, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
|
Schaffner EMC |
LINE FILTER 480VAC 10A CHASS MNT |
6,642 |
|
FN 3270 | Three Phase (Delta) | Single Stage | - | 480V | 300V | 520V | 10A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 1.2KVDC 75A CHASS |
8,064 |
|
FN 2200 | DC | Single Stage | 1200V (1.2kV) | - | - | - | 75A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |