Apply Filters
CategoryPassive Components / Filters / Power Line Filter Modules
Records 5,440
Page 38/182
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
KEMET |
LINE FILTER 440VDC 250VAC 40A CH |
7,632 |
|
F.LL.DH | Single Phase | Single Stage | 440V | 250V | - | - | 40A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M6) | - |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 16A CHASS |
7,722 |
|
FN 2070 | Single Phase | Two Stage | - | 110V, 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2.8mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
7,902 |
|
VP | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
4,824 |
|
T | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 9.5mH |
|
|
Schaffner EMC |
LINE FILTER 250VDC/VAC 30A CHAS |
6,072 |
|
FN 2090 | Single Phase | Two Stage | 250V | 250V | - | - | 30A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.5mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 16A CHASS |
5,850 |
|
FN 2070 | Single Phase | Two Stage | - | 110V, 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 2.8mH |
|
|
Schaffner EMC |
LINE FILTER 520/300VAC 8A DIN |
7,308 |
|
FN 2412 | Single Phase | Single Stage | - | 520V, 300V | - | - | 8A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 520/300VAC 16A CHASS |
8,334 |
|
FN 2410 | Single Phase | Single Stage | - | 520V, 300V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 16A CHASS |
3,798 |
|
FN 2080 | Single Phase | Two Stage | - | 110V, 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2.8mH |
|
|
KEMET |
LINE FILTER 440VDC 250VAC 25A CH |
7,884 |
|
F.LL.DH | Single Phase | Single Stage | 440V | 250V | - | - | 25A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M6) | - |
|
|
KEMET |
LINE FILTER 440VDC 250VAC 16A CH |
8,316 |
|
F.LL.DH | Single Phase | Single Stage | 440V | 250V | - | - | 16A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M6) | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 16A CHAS |
8,892 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 16A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
6,786 |
|
Q | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 25A CHASS |
6,624 |
|
FN 2070 | Single Phase | Two Stage | 250V | 250V | - | - | 25A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2mH |
|
|
Cosel |
LINE FILTER 500VAC 6A CHASSIS |
6,858 |
|
TAC | Three Phase (Delta) | Single Stage | - | 500V | - | - | 6A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 20A CHAS |
5,940 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 520/300VAC 16A DIN |
6,084 |
|
FN 2412 | Single Phase | Single Stage | - | 520V, 300V | - | - | 16A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
TDK-EPCOS |
LINE FILTER 250V 30A CHASSIS MNT |
8,730 |
|
B84142A | Single Phase | Two Stage | - | - | - | - | 30A | - | General Purpose | cULus, ENEC | - | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER FN2000 SERIES |
8,928 |
|
* | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
Schaffner EMC |
LINE FILTER 520/300VAC 25A CHASS |
7,020 |
|
FN 2410 | Single Phase | Single Stage | - | 520V, 300V | - | - | 25A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Delta Electronics |
LINE FILTER 16A CHASSIS MOUNT |
5,724 |
|
TDP | Three Phase (Delta) | Single Stage | - | - | - | - | 16A | - | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 4.3mH |
|
|
Cosel |
LINE FILTER 500VAC 20A CHASSIS |
6,282 |
|
TAC | Three Phase (Delta) | Single Stage | - | 500V | - | - | 20A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Delta Electronics |
LINE FILTER 480VAC CHASSIS MOUNT |
5,652 |
|
TYT | Three Phase (Wye) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Block | 950µH |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
4,626 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
5,778 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
8,334 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
4,356 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
6,768 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
6,696 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Cosel |
LINE FILTER 250VDC/VAC 30A CHAS |
3,888 |
|
NBH | Single Phase | Two Stage | 250V | 250V | 250V | - | 30A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |