CategoryPassive Components / Filters / Power Line Filter Modules
Records 5,440
Page 107/182
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approvals | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Curtis Industries |
LINE FILTER 250VAC 1A CHASS MNT |
4,860 |
|
F1350 | Single Phase | Two Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 30A CHASS |
97 |
|
RSEN | Single Phase | Single Stage | 250V | 250V | - | - | 30A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
7,020 |
|
H | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | UL, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 440µH |
|
|
Altran Magnetics |
LINE FILTER 250VAC 6A CHASS MNT |
3,330 |
|
AMI-M11G | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 18.5mH |
|
|
Altran Magnetics |
LINE FILTER 250VAC 3A CHASS MNT |
7,092 |
|
AMI-M12J | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Wire Leads | 32.18mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A CHASS MNT |
4,050 |
|
DK | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 1.86mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
8,100 |
|
DK | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.76mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
4,392 |
|
DK | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 516µH |
|
|
Delta Electronics |
LINE FILTER 115/250VAC 16A CHASS |
7,362 |
|
DP | Single Phase | Two Stage | - | 115V, 250V | - | - | 16A | 50/60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Threaded Post (8-32) | - |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 6A CHASS |
4,032 |
|
RSHN | Single Phase | Two Stage | 250V | 250V | - | - | 6A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Bulgin |
LINE FILTER 250VAC 3A CHASS MNT |
7,884 |
|
PS02 | Single Phase | Single Stage | - | 250V | - | - | 3A | 50 ~ 400Hz | General Purpose | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | 1.8mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 2A TH |
8,100 |
|
Y | Single Phase | Single Stage | - | 250V | - | - | 2A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Through Hole | PC Pins | 5.7mH |
|
|
Delta Electronics |
LINE FILTER 115/250VAC 30A CHASS |
3,276 |
|
DB | Single Phase | Single Stage | - | 115V, 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Threaded Post (8-32) | 670µH |
|
|
Altran Magnetics |
LINE FILTER 250VAC 4A CHASS MNT |
2,592 |
|
AMI-M11H | Single Phase | Single Stage | - | 250V | - | - | 4A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7.06mH |
|
|
Altran Magnetics |
LINE FILTER 110/250VAC 16A CHAS |
4,392 |
|
AMI-28 | Single Phase | Two Stage | - | 250V | - | - | 16A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M4), Wire Leads | 2.84mH |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 6A DIN |
2,790 |
|
RSAN | Single Phase | Single Stage | 250V | 250V | - | - | 6A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 20A CHASS |
4,932 |
|
RSAN | Single Phase | Single Stage | 250V | 250V | - | - | 20A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 20A CHASS |
2,214 |
|
RSAN | Single Phase | Single Stage | 250V | 250V | - | - | 20A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 16A DIN |
8,280 |
|
RSEN | Single Phase | Single Stage | 250V | 250V | - | - | 16A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
|
Altran Magnetics |
LINE FILTER 250VAC 3A CHASS MNT |
7,704 |
|
AMI-M11F | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 36.8mH |
|
|
Delta Electronics |
LINE FILTER 115/250VAC 20A CHASS |
6,066 |
|
DP | Single Phase | Two Stage | - | 115V, 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | 600µH |
|
|
Altran Magnetics |
LINE FILTER 250VAC 16A CHASS MNT |
7,686 |
|
AMI-26 | Single Phase | Two Stage | - | 250V | - | - | 16A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.3mH |
|
|
Altran Magnetics |
LINE FILTER 250VAC 16A CHASS MNT |
7,776 |
|
AMI-26 | Single Phase | Two Stage | - | 250V | - | - | 16A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.3mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A TH |
5,652 |
|
Y | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Through Hole | PC Pins | 9.57mH |
|
|
Altran Magnetics |
LINE FILTER 250VAC 8A CHASS MNT |
7,272 |
|
AMI-M12N | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect, Wire Leads | 48.8mH |
|
|
Curtis Industries |
LINE FILTER 250VAC 20A CHASS MNT |
5,904 |
|
F1250 | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | - | - | Chassis Mount | Threaded Post (8-32) | - |
|
|
Cosel |
LINE FILTER 50VDC 10A DIN RAIL |
2,808 |
|
SNR | DC | Single Stage | 50V | - | - | - | 10A | - | General Purpose | cURus, TUV | -40°C ~ 71°C | DIN Rail | Terminal Block | - |
|
|
Cosel |
LINE FILTER 50VDC 10A DIN RAIL |
3,816 |
|
SNR | DC | Single Stage | 50V | - | - | - | 10A | - | General Purpose | cURus, TUV | -40°C ~ 71°C | DIN Rail | Terminal Block | - |
|
|
Altran Magnetics |
LINE FILTER 250VAC 3A CHASS MNT |
7,560 |
|
AMI-M12F | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Wire Leads | 48.8mH |
|
|
Bulgin |
LINE FILTER 250VAC 10A CHASS MNT |
8,226 |
|
PS02 | Single Phase | Single Stage | - | 250V | - | - | 10A | 50 ~ 400Hz | General Purpose | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | 170µH |