TPP 40-331M3

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

3

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

15V

Voltage - Output 2

5V

Voltage - Output 3

-15V

Voltage - Output 4

-

Current - Output (Max)

2.67A, 4A, 500mA

Power (Watts)

68W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

88%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm)

TPP 40-321M2

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

3

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

12V

Voltage - Output 2

5V

Voltage - Output 3

-12V

Voltage - Output 4

-

Current - Output (Max)

3.34A, 4A, 500mA

Power (Watts)

66W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

88%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm)

TPP 40-3512

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

3

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

24V

Voltage - Output 2

5V

Voltage - Output 3

12V

Voltage - Output 4

-

Current - Output (Max)

1.67A, 4A, 500mA

Power (Watts)

66W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

86%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm)

TPP 40-231

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

2

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

15V

Voltage - Output 2

5V

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

2.67A, 4A

Power (Watts)

60W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

88.5%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm)

TPP 40-221

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

2

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

12V

Voltage - Output 2

5V

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

3.34A, 4A

Power (Watts)

60W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

89%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm)

TPP 40-251

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

2

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

24V

Voltage - Output 2

5V

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

1.67A, 4A

Power (Watts)

60W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

86%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm)

TPP 40-105

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

1

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

5V

Voltage - Output 2

-

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

8A

Power (Watts)

40W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

90%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Adjustable Output, Universal Input

Mounting Type

Chassis Mount

Size / Dimension

3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm)

TPP 40-124

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

1

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

24V

Voltage - Output 2

-

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

1.67A

Power (Watts)

40W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

92%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Universal Input

Mounting Type

Chassis Mount

Size / Dimension

3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm)

TPP 40-115

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

1

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

15V

Voltage - Output 2

-

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

2.67A

Power (Watts)

40W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

92%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Universal Input

Mounting Type

Chassis Mount

Size / Dimension

3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm)

TPP 40-112

Traco Power

Manufacturer

Traco Power

Series

TPP 40 (40W)

Type

Enclosed

Number of Outputs

1

Voltage - Input

85 ~ 264 VAC, 120 ~ 370 VDC

Voltage - Output 1

12V

Voltage - Output 2

-

Voltage - Output 3

-

Voltage - Output 4

-

Current - Output (Max)

3.34A

Power (Watts)

40W

Applications

Medical

Voltage - Isolation

4kV

Efficiency

92%

Operating Temperature

-40°C ~ 85°C (With Derating)

Features

Universal Input

Mounting Type

Chassis Mount

Size / Dimension