Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 3V Voltage - Input (Max) 3.6V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 66mA, 66mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 3V Voltage - Input (Max) 3.6V Voltage - Output 1 12V Voltage - Output 2 -12V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 85mA, 85mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 3V Voltage - Input (Max) 3.6V Voltage - Output 1 3.3V Voltage - Output 2 -3.3V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 300mA, 300mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 70 ~ 78% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 3V Voltage - Input (Max) 3.6V Voltage - Output 1 9V Voltage - Output 2 -9V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 111mA, 111mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 84% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 3V Voltage - Input (Max) 3.6V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 200mA, 200mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 82% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 21.6V Voltage - Input (Max) 26.4V Voltage - Output 1 9V Voltage - Output 2 -9V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 111mA, 111mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 84% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 21.6V Voltage - Input (Max) 26.4V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 200mA, 200mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 82% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 21.6V Voltage - Input (Max) 26.4V Voltage - Output 1 12V Voltage - Output 2 -12V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 85mA, 85mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 13.5V Voltage - Input (Max) 16.5V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 66mA, 66mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 13.5V Voltage - Input (Max) 16.5V Voltage - Output 1 12V Voltage - Output 2 -12V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 85mA, 85mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 13.5V Voltage - Input (Max) 16.5V Voltage - Output 1 3.3V Voltage - Output 2 -3.3V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 300mA, 300mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 70 ~ 78% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |
Manufacturer Recom Power Series ECONOLINE RV/R (2W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 21.6V Voltage - Input (Max) 26.4V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 66mA, 66mA Power (Watts) 2W Voltage - Isolation 8kV Applications ITE (Commercial), Medical Features SCP Operating Temperature -40°C ~ 85°C Efficiency 86% Mounting Type Through Hole Package / Case 24-DIP Module, 14 Leads Size / Dimension 1.27" L x 0.58" W x 0.45" H (32.4mm x 14.7mm x 11.4mm) Supplier Device Package - Control Features |