PA18CAT20PAM1SA Datasheet
![PA18CAT20PAM1SA Datasheet Page 1](http://pneda.ltd/static/datasheets/images/91/pa18cat20pam1sa-0001.webp)
![PA18CAT20PAM1SA Datasheet Page 2](http://pneda.ltd/static/datasheets/images/91/pa18cat20pam1sa-0002.webp)
![PA18CAT20PAM1SA Datasheet Page 3](http://pneda.ltd/static/datasheets/images/91/pa18cat20pam1sa-0003.webp)
![PA18CAT20PAM1SA Datasheet Page 4](http://pneda.ltd/static/datasheets/images/91/pa18cat20pam1sa-0004.webp)
![PA18CAT20PAM1SA Datasheet Page 5](http://pneda.ltd/static/datasheets/images/91/pa18cat20pam1sa-0005.webp)
![PA18CAT20PAM1SA Datasheet Page 6](http://pneda.ltd/static/datasheets/images/91/pa18cat20pam1sa-0006.webp)
Manufacturer Carlo Gavazzi Inc. Series PA Sensing Method Through-Beam Sensing Distance 787.402" (20m) Voltage - Supply 10V ~ 30V Response Time 1ms Output Configuration PNP Connection Method Connector Ingress Protection IP67, IP69K Cable Length - Light Source Infrared (850nm) Adjustment Type Adjustable, 210° Turn Potentiometer Operating Temperature -25°C ~ 60°C |
Manufacturer Carlo Gavazzi Inc. Series PA Sensing Method Through-Beam Sensing Distance 629.921" (16m) Voltage - Supply 10V ~ 30V Response Time 1ms Output Configuration PNP Connection Method Cable Ingress Protection IP67, IP69K Cable Length 78.74" (2m) Light Source Infrared (850nm) Adjustment Type Adjustable, 210° Turn Potentiometer Operating Temperature -25°C ~ 60°C |
Manufacturer Carlo Gavazzi Inc. Series PA Sensing Method Through-Beam Sensing Distance 787.402" (20m) Voltage - Supply 10V ~ 30V Response Time 1ms Output Configuration PNP Connection Method Cable Ingress Protection IP67, IP69K Cable Length 78.74" (2m) Light Source Infrared (850nm) Adjustment Type Adjustable, 210° Turn Potentiometer Operating Temperature -25°C ~ 60°C |
Manufacturer Carlo Gavazzi Inc. Series PA Sensing Method Through-Beam Sensing Distance 629.921" (16m) Voltage - Supply 10V ~ 30V Response Time 1ms Output Configuration - Connection Method Cable Ingress Protection IP67, IP69K Cable Length 78.74" (2m) Light Source Infrared (850nm) Adjustment Type Adjustable, 210° Turn Potentiometer Operating Temperature -25°C ~ 60°C |
Manufacturer Carlo Gavazzi Inc. Series PA Sensing Method Through-Beam Sensing Distance 787.402" (20m) Voltage - Supply 10V ~ 30V Response Time 1ms Output Configuration - Connection Method Cable Ingress Protection IP67, IP69K Cable Length 78.74" (2m) Light Source Infrared (850nm) Adjustment Type Adjustable, 210° Turn Potentiometer Operating Temperature -25°C ~ 60°C |
Manufacturer Carlo Gavazzi Inc. Series PA Sensing Method Through-Beam Sensing Distance 787.402" (20m) Voltage - Supply 10V ~ 30V Response Time 1ms Output Configuration - Connection Method Connector Ingress Protection IP67, IP69K Cable Length - Light Source Infrared (850nm) Adjustment Type Adjustable, 210° Turn Potentiometer Operating Temperature -25°C ~ 60°C |