DRB50151 Datasheet
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 15V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 3.4A Power (Watts) 51W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 90% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 1.18" W x 2.95" H (89.9mm x 30.0mm x 74.9mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 4.2A Power (Watts) 100W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 91% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.94" L x 1.77" W x 2.95" H (100.0mm x 45.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 5V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 6A Power (Watts) 30W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 80% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 1.18" W x 2.95" H (90.0mm x 30.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 48V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 1.05A Power (Watts) 50W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 91% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 1.18" W x 2.95" H (90.0mm x 30.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 630mA Power (Watts) 15W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 90% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 0.71" W x 2.95" H (90.0mm x 18.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 2.1A Power (Watts) 50W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 90% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 1.18" W x 2.95" H (90.0mm x 30.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 12V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 2.5A Power (Watts) 30W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 88% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 0.83" W x 2.95" H (90.0mm x 21.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 12V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 4.2A Power (Watts) 50W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 90% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 1.18" W x 2.95" H (90.0mm x 30.0mm x 75.0mm) |
TDK-Lambda Manufacturer TDK-Lambda Americas Inc. Series DRB (15-100W) Type Enclosed Number of Outputs 1 Voltage - Input 85 ~ 264 VAC, 120 ~ 373 VDC Voltage - Output 1 24V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 1.25A Power (Watts) 30W Applications Hazardous Locations, Industrial, ITE (Commercial) Voltage - Isolation 3kV Efficiency 90% Operating Temperature -20°C ~ 70°C (With Derating) Features Adjustable Output, Universal Input Mounting Type DIN Rail Size / Dimension 3.54" L x 0.83" W x 2.95" H (90.0mm x 21.0mm x 75.0mm) |